Sign In | Join Free | My himfr.com
Home > Shell And Tube Heat Exchanger >

Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling

Wuhan Qiaoxin Refrigeration Equipment CO., LTD
Contact Now
    Buy cheap Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling from wholesalers
     
    Buy cheap Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling from wholesalers
    • Buy cheap Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling from wholesalers

    Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling

    Ask Lasest Price
    Brand Name : GREEFOUN
    Model Number : QXU110S8
    Certification : CE
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 100000pieces/year
    Delivery Time : within 15days
    • Product Details
    • Company Profile

    Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling

    Water to Water Tube Heat Exchanger


    Water - Cooled Evaporator


    Condenser and evaporator in the structure can be exactly the same, to see where the use of the.


    Generally in the unit cooling, the refrigerant evaporates inside, that is, evaporator, refrigerant


    condensation in the inside, called the condenser.


    In the case of the same heat transfer medium, the condenser of a single chiller is generally larger than the


    evaporator and the heat transfer area ratio is about 5.5: 4.5.


    Because the condenser but also a scattered energy into the heat.


    The two are roughly speaking, there is no difference, are the heat exchanger, but the use of different


    purposes, the condenser used to discharge heat, the evaporator used to absorb heat.


    Carefully speaking, there are differences:


    In the condenser design, should be sub-channel, different road entrance should be as close as possible,


    exports should also be as close as possible, imports and exports should also be as far as possible to


    avoid due to heat loss and loss of part of the heat transfer to avoid uneven distribution of traffic The In the


    actual design, if the split more than two, should be used centralized dispenser and collectors, as far as


    possible between the different flow of uniform flow. The piping of the different flow paths is preferably the


    same, and should flow evenly across the windward side and the leeward side so that the heat transfer is


    uniform.


    For the evaporator, the requirements are similar, relatively speaking, can be simple, the most common is


    the liquid into the liquid part of the split head, divided into more road, and the liquid head must be installed


    vertically. The condenser is not split head, the use of sub-gas header.


    STEAM TO WATER HEAT EXCHANGER


    CAPACITY: 1000KW TO 4000KW


    ModelCapacity (KW)Dimension (mm)Weight (kg)
    DT1TACEFH1H2
    QXSW60S10100027316002053120360150100350240297
    QXSW70S12125032520322498150406180120350240357
    QXSW80S12140032520322498150406180120350240372
    QXSW90S12160032520322498150406180120350240387
    QXSW100S12180032520322498150406180120350240412
    QXSW120S14210035520322555150440180120400290494
    QXSW140S14250035525003023180440180120400290517
    QXSW180S16320042625002951180530260150260260729
    QXSW220S16400042625002951180530260150260260784

    ModelS1S2W
    SpecificationConnection typeSpecificationConnection typeSpecificationConnection type
    QXSW60S10DN100male flangeDN65male flangeDN80male flange
    QXSW70S12DN100male flangeDN65male flangeDN80male flange
    QXSW80S12DN125male flangeDN80male flangeDN100male flange
    QXSW90S12DN125male flangeDN80male flangeDN100male flange
    QXSW100S12DN125male flangeDN80male flangeDN100male flange
    QXSW120S14DN125male flangeDN80male flangeDN100male flange
    QXSW140S14DN125male flangeDN80male flangeDN100male flange
    QXSW180S16DN150male flangeDN100male flangeDN125male flange
    QXSW220S16DN150male flangeDN100male flangeDN125male flange

    CONDENSER SERIES SINGLE CIRCUIT


    CAPACITY: 75RT TO 100RT


    ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
    DT1TACEH1H2
    QXC75S12A7528.3503252032248512036018035024033557.2
    QXC80S12A8030.2403252032248512040618035024034361
    QXC85S12A8532.1303252032248512040618035024035064.1
    QXC90S12A9034.0203252032248512040618035024036468
    QXC95S12A9535.9103252032248512040618035024037272.1
    QXC100S12A10037.8003252500296612040618035024037976

    ModelS (Vent)

    P (fluoride inlet)

    Copper pipe diameter (inch)

    L(fluoride outlet)

    Copper pipe diameter (inch)

    W (standard port)W (optional port)
    FPT(inner pipe thread)Male flangeMale flange
    QXC75S12A3/82-1/81-3/8DN80DN100
    QXC80S12A3/82-1/81-3/8DN80DN100
    QXC85S12A3/82-5/81-3/8DN100DN100
    QXC90S12A3/82-5/81-3/8DN100DN100
    QXC95S12A3/82-5/81-3/8DN100DN100
    QXC100S12A3/83-1/81-5/8DN100DN100

    WATER TO WATER HEAT EXCHANGER


    CAPACITY: 100KW TO 400KW


    ModelCapacity (KW)Dimension (mm)Weight (kg)
    DT1TACEFG
    QXWW8S6100168762858801859280051
    QXWW15S620016812701366801859280078
    QXWW20S8300219127013801002381138030/0118
    QXWW30S8400219127013801002381138030/0131

    ModelW1W2
    SpecificationConnection typeSpecificationConnection type
    QXWW8S6G1-1/2internal pipe threadG1-1/2internal pipe thread
    QXWW15S6G1-1/2internal pipe threadG1-1/2internal pipe thread
    QXWW20S8G2internal pipe threadG2internal pipe thread
    QXWW30S8G2-1/2internal pipe threadG2-1/2internal pipe thread


    COOPERATED CLENTS

    Quality Double System Shell And Tube Heat Exchanger Water To Water Durable Modeling for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Wuhan Qiaoxin Refrigeration Equipment CO., LTD
    *Subject:
    *Message: