    Double Circuit Tube Shell Heat Exchanger , Loose Flange Water Cooled Condenser

    Ask Lasest Price
    Brand Name : GREEFOUN
    Model Number : QXU34
    Certification : CE
    Payment Terms : TT, L/C, Western Union
    Supply Ability : 100000pieces/year
    Delivery Time : within 15days
    • Product Details
    • Company Profile

    Double Circuit Tube Shell Heat Exchanger , Loose Flange Water Cooled Condenser

    Double Circuit Corrosion Resistant


    Tube Heat Exchanger for Central Air Conditioning


    Double Circuit Corrosion Resistant Tube Heat Exchanger for Central Air Conditioning is suitable for water


    cooled unit, water source heat pump, air cooled pump and air cooled heat pump unit.

    The product is applying for refrigerants of R22, R134a, R407C and R410A etc.

    The referigerating medium is for tap water, underground water, river water and sea water or brine, water

    and glycol solution, sulfate solution, etc.

    For heat exchange tube, copper pipe, copper nickel alloy tube, aluminum brass tube, stainless steel tube,

    etc. The shell raw material mainly are seamless steel tube, stainless steel pipe.


    1, Heat exchange tube: four main tube type.

    (1) ∅ within 3/8 "thread copper coil, it is mainly used for" U "type tube evaporator.

    (2) ∅ within 1/2 "threaded straight copper tube, straight tube is mainly used for dry-type evaporator.

    (3) ∅ 1/2 "corrugated straight stainless steel tube, straight tube is mainly used in food industry of dry

    evaporator.

    (4) ∅ 5/8 "inside outside screw wing efficient copper tube, it is mainly used for air precooling industry dry

    evaporator.

    2, shell raw material:

    There are two of the major materials:

    (1) # 20 seamless steel tube, mainly used for all kinds of load - more than 20 ℃ cold agent.

    (2) 304/316 l stainless steel tube, it is mainly used for food and low temperature (below 25 ℃, higher than

    40 ℃) of the refrigerant, 316 l can also be used for cooling load of the sulfate for industry.

    3, interface:

    U SHAPED TUBE DRY EVAPORATOR (DOUBLE SYSTEM)


    CAPACITY: 35KW TO 95KW


    ModelsQXU35D6QXU47D6QXU56D6QXU65D8QXU80D8QXU95D8

    Rated data

    Refrigerant R22

    ti=12°C te=2°C

    tu=7°C Dts=5°C

    QnKW354756658095
    Kcal/h(×103 )30.240.448.256.768.881.7
    Wnm3 /h689.611.413.816.4
    Wmm3 /h1011.41214.51921
    Dpnbar0.270.410.350.390.420.46

    ModelsQXU35D6QXU47D6QXU56D6QXU65D8QXU80D8QXU95D8
    Dimension(mm)A127514071431143116311781
    B168168168168219219
    C107107161161200200
    D104011901030118013801530
    E200200200240240240
    VentS11/21/21/21/21/21/2
    OutletS21/21/21/21/21/21/2
    ConnectionW(DN)505050506565
    D1(mm)161622222222
    D2(mm)222235353535
    P(kg)72788893125136

    Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

    Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


    U SHAPED TUBE DRY EVAPORATOR (SINGLE CIRCUIT)


    CAPACITY: 120KW TO 270KW


    ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10

    Rated data

    Refrigerant R22

    ti=12°C te=2°C

    tu=7°C Dts=5°C

    QnKW120135155185220270
    Kcal/h(×103 )103.2116133.3159180232
    Wnm3 /h20.323.226.731.837.846.4
    Wmm3 /h252830414365
    Dpnbar0.410.440.370.360.430.42

    ModelsQXU120S8QXU135S8QXU155S8QXU185S10QXU220S10QXU270S10
    Dimension(mm)A181521152315232026542654
    B219219219273273273
    C180180180200234234
    D153018302030200022802280
    E240240240300300300
    VentS11/21/21/21/21/21/2
    OutletS21/21/21/21/21/21/2
    ConnectionW(DN)808080100100100
    D1(mm)353535353535
    D2(mm)545467678080
    P(kg)145155163232279289

    Qn-rated refrigerating capacity Wn-cooling water flow Wm-maximum cooling water flow

    Dpn-pressure drop of recirculating cooling water Dts-overheat temperature


    CONDENSER SERIES SINGLE CIRCUIT


    CAPACITY: 40RT TO 70RT


    ModelRefrig. ton (RT)Refrig. ton (104kcal/h)Dimension (mm)Weight (kg)Max. water flow
    DT1TACEH1H2
    QXC40S10A4015.122731600205312036015035024020431
    QXC45S10A4517.012731600205312036015035024021235
    QXC50S10A5018.902732032248512036015035024024038.5
    QXC55S10A5520.792732032248512036015035024024942.5
    QXC60S10A6022.682732032248512036015035024025646
    QXC65S10A6524.572732032248512036015035024026449.2
    QXC70S10A7026.462732032248512036015035024027053.5

    ModelS (Vent)

    P (fluoride inlet)

    Copper pipe diameter (inch)

    L(fluoride outlet)

    Copper pipe diameter (inch)

    W (standard port)W (optional port)
    FPT(inner pipe thread)Male flangeMale flange
    QXC40S10A3/81-5/81-1/8DN65DN65
    QXC45S10A3/81-5/81-1/8DN65DN65
    QXC50S10A3/81-5/81-1/8DN65DN80
    QXC55S10A3/81-5/81-1/8DN65DN80
    QXC60S10A3/81-5/81-3/8DN65DN80
    QXC65S10A3/81-5/81-3/8DN65DN80
    QXC70S10A3/82-1/81-3/8DN80DN80